SCCM Console - EventID 10009 REPLACEPROVIDERMACHINE
I have the following message in the event log and i can't start the Microsoft System Center Configuration Manager Console 2007.
I'm fix the error with this steps:
You can find more information at this link -> https://support2.microsoft.com/kb/317872/en-us
I'm fix the error with this steps:
- Running wbemtest.exe with admin rights
- Click Connect, type \\siteserver\root\sms and then click Login
- Click Enum Classes, click Recursive and then click OK.
- In the Query Result list, double-click SMS_ProviderLocation
- Click Instances and then double-click the line that contains the target site code
- For example, SMS_ProviderLocation.SiteCode="xxx"
- In the Properties section, locate the NamespacePath line. You may have to double-click this line to see the whole line.
- Copy the NamespacePath value to the clipboard.
- For example, copy the following value: \\server_name\root\sms\site_xxx
You can find more information at this link -> https://support2.microsoft.com/kb/317872/en-us